2 Hour Fire Rated PROMINA® 60 Steel Duct Cladding
The 2 Hour Fire Rated PROMINA® 60 Steel Duct Cladding is designed to provide tested fire protection for steel ventilation, smoke extraction and kitchen extract ducts. It helps maintain fire compartmentation where ductwork passes through fire-rated walls and floors without the use of fire dampers.
Supplied by PROSAFE, this PROMAT system is constructed using a single layer of 12mm PROMINA® 60 calcium silicate board together with galvanised steel angles, steel channel collars and 50mm mineral wool insulation. Board joints are sealed using PROMINA® 60 cover strips or PROMASEAL®-A Acrylic Sealant in accordance with the approved tested assembly.
When installed as the approved tested assembly, the system provides 120 minutes of fire resistance and achieves a Fire Resistance Level (FRL) of 120/120/120. The system has been tested and assessed in accordance with BS 476 Part 24:1987 for both Duct Type A (external fire) and Duct Type B (internal and external fire) performance.
Suitable for commercial, industrial, institutional, residential and high rise developments, this system provides a reliable passive fire protection solution for projects requiring compliant fire resistant ductwork.
The 2 Hour Fire Rated PROMINA® 60 Steel Duct Cladding is suitable for a variety of building types, including:
-
Commercial buildings
-
Industrial facilities
-
Institutional buildings
-
Residential developments
-
High rise buildings
-
Ventilation duct systems
-
Smoke extraction duct systems
-
Kitchen extract duct systems
-
Service risers and plant rooms
Technical Specifications
Title | Description |
|---|---|
Fire Resistance | 120 Minutes |
Fire Exposure | Duct Type A (External Fire) and Duct Type B (Internal & External Fire) |
Fire Resistance Level | FRL 120/120/120 |
Test Standard | BS 476 Part 24:1987 |
Board | PROMINA® 60 |
System Type | Fire Rated Steel Duct Cladding |
System Thickness | Based on the approved tested assembly |
Applications | Commercial, Industrial, Institutional, Residential, High Rise Buildings, Ventilation, Smoke Extraction and Kitchen Extract Ducts |
Acoustic Performance | Not Published |
Detailed Systems & Brochures
Frequently Asked Questions
Is this system tested?
Yes. This system has been tested to BS 476 Part 24:1987 for fire resistant ductwork and provides 120 minutes of fire resistance when installed in accordance with the approved tested assembly. It has been tested for both Duct Type A and Duct Type B applications and is supported by the relevant fire test documentation for BOMBA submission where applicable.
Do fire rated systems require certificate renewal?
No. Building owners do not need to renew the fire test certification. The certification is maintained by the system manufacturer (PROMAT), while the installed system should always follow the tested assembly and manufacturer recommendations.
How much does this system cost?
The cost depends on factors such as the project size, duct dimensions and specification requirements. Contact PROSAFE for a project-specific quotation and technical advice here.
Why choose PROSAFE for passive fire protection systems?
PROSAFE supplies PROMAT fire rated systems that are rigid, lightweight, moisture resistant and supported by tested documentation. With a wide range of system options and practical technical support, we help make system selection easier for projects across Malaysia.
Is this system suitable for smoke exhaust ducts?
Yes. The published PROMINA® 60 system is suitable for ventilation, smoke extraction and kitchen extract duct applications when installed in accordance with the approved tested assembly.
PROMINA® 60 or PROMATECT®-H, which should I choose?
Both are tested PROMAT fire rated duct systems supplied by PROSAFE. The appropriate system depends on your project requirements and the approved tested assembly. Contact PROSAFE for help selecting the most suitable system here.