top of page

4 Hour Fire Rated Steel Stud Partition

Where longer fire resistance is required for compartment walls, a steel stud partition provides a practical solution while maintaining a lightweight construction suitable for a wide range of building projects.

The 4 Hour Fire Rated Steel Stud Partition supplied by PROSAFE, based on the selected design, is constructed using two layers of 9mm PROMINA®-60 board fixed to both sides of a steel stud framework with mineral wool insulation installed within the cavity. When installed in accordance with the tested construction, the complete assembly has a system thickness of 136mm.

Tested to BS 476 Part 22:1987 for non-loadbearing construction, the system provides 240 minutes of fire resistance from both sides and achieves a Fire Resistance Level (FRL) of -/240/240 when installed as the approved tested assembly.

Suitable for commercial, industrial, institutional and residential developments, this partition system provides a dependable solution where extended fire compartmentation is required.

The 4 Hour Fire Rated Steel Stud Partition is suitable for a variety of building types, including:

  • Commercial buildings

  • Industrial facilities

  • Institutional buildings

  • Residential developments

  • High rise buildings

  • Refurbishment and restoration projects

Technical Specifications

Title
Description
Fire Resistance
240 Minutes
Fire Exposure
Both Sides
Fire Resistance Level
FRL -/240/240
Test Standard
BS 476 Part 22:1987 (Non-loadbearing)
Board
PROMINA®-60
System Type
Steel Stud Partition
System Thickness
Nominal 136mm
Applications
Commercial, Industrial, Institutional, Residential, High Rise and Refurbishment Projects
Acoustic Performance
Not published

Frequently Asked Questions

Is this system tested?

Yes. This system has been tested to BS 476 Part 22:1987 for non-loadbearing construction and provides 240 minutes of fire resistance when installed in accordance with the tested assembly. It is supported by the relevant test documentation and is accepted for BOMBA submission where applicable.

Do fire rated systems require certificate renewal?

No. Building owners do not need to renew the fire test certification. The certification is maintained by the system manufacturer (PROMAT), while the installed system should always follow the tested assembly and manufacturer recommendations.

How much does this system cost?

The cost depends on factors such as the project size, partition dimensions and specification requirements. Contact PROSAFE for a project-specific quotation and technical advice here.

Why choose PROSAFE for passive fire protection systems?

PROSAFE supplies PROMAT fire rated systems that are rigid, lightweight, moisture resistant and supported by tested documentation. With a wide range of system options and practical technical support, we help make system selection easier for projects across Malaysia.

Can this partition be installed above 4 metres in height?

Yes. However, where the partition height exceeds 4000mm, the size of the steel channels should be determined in accordance with PROMAT recommendations. Contact PROSAFE for project-specific technical advice here.

Which side of the partition provides fire protection?

This system provides 240 minutes of fire resistance from both sides when installed in accordance with the approved tested assembly.